Ast AST20PT Datasheet Manual do Utilizador

Consulte online ou descarregue Manual do Utilizador para Sensores Ast AST20PT Datasheet. AST AST20PT Datasheet User Manual Manual do Utilizador

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 3
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 0
TM
American Sensor Technologies 450 Clark Dr., Mt. Olive, NJ 07828 phone (973) 448-1901 fax (973) 448-1905 email: [email protected]
Environmental Data
Operating Ambient Temperature -40 to 85°C (-40 to 185°F)
Operating Media Temperature -55 to 125°C (-67 to 257°F)
Storage Temperature -50 to 125°C (-58 to 257°F)
Thermal Limits
Compensated Range 0-70°C (32 to 158°F)
TC Zero < ± 0.5% FS
TC Span < ± 0.5% FS
Other
Shock 100G, 11msec, 1/2 sine
Vibration 10G peak, 20 to 2000Hz
EMI/RFI Protection: Yes
Rating: IP-66
Electrical Data
Output 4-20mA
+
0-5V, 1-5V 0-10V, 1-10V 0.5-4.5V Ratiometric
Excitation 10-28VDC 10-28VDC 15-30VDC 5VDC, Regulated
Current Consumption: - < 10mA < 10mA < 10mA
Sampling Rate 400Hz 400Hz 400Hz 400Hz
Output Noise: < 1mV, RMS < 1mV, RMS < 1mV, RMS < 1mV, RMS
Zero Offset < ± 0.5% FS < ± 0.5% FS < ± 0.5% FS < ± 0.5% FS
Span Tolerance < ± 0.5% FS < ± 0.5% FS < ± 0.5% FS < ± 0.5% FS
Output Load: 0-800 Ohms@10-28VDC 5k Ohms, min. 5k Ohms, min. 5k Ohms, min.
Reverse Polarity Protection Yes Yes Yes Yes
Applications
Aerospace
Analytical Instruments
Hydraulics
Hydrogen (Consult factory
for media compatibility)
Labs / Metrology
Medical
Military
Test Stands
Benefits
ASIC Compensation
Superb Temperature Performance
Real Time Thermal Compensation
Real Time Linearity Correction
Turndown Capability
The AST20PT is a digitally compensated pressure and temperature dual
output transmitter, offering measurments from a single process point,
reducing process penetration points and leaks. Krystal Bond™ Technology
alone offers excellent non-linearity and non-repeatability performance. When
it is combined with the ASIC, the AST20PT steps into its own league of high
performance pressure sensing at an affordable price.
AST20PT
Precision Pressure & Temperature Transmitter
Performance @ 25°C (77°F)
Accuracy* < ±0.1% BFSL (<±0.2% BFSL over 15,000 PSI)
Stability (1 year) ±0.1% FS, typical
Proof Pressure ** 2X Rated Pressure, standard
Burst Pressure 5X or 50,000 PSI, whichever is less
Pressure Cycles > 100 Million
* Accuracy includes non-linearity, hysteresis & non-repeatability **For higher proof pressures, contact factory
+
For units with loop-powered 4-20mA output, the pressure loop must be powered or the temperature output will not operate.
PRESSURE & TEMPERATURE
Vista de página 0
1 2 3

Resumo do Conteúdo

Página 1 - PRESSURE & TEMPERATURE

TMAmerican Sensor Technologies • 450 Clark Dr., Mt. Olive, NJ 07828 • phone (973) 448-1901 • fax (973) 448-1905 • email: [email protected]

Página 2 - AST20PT 1 00500 P E3 1 H 00A

TMwww.astsensors.com © 2014 American Sensor Technologies Inc. AST20PT 08/12/2014. All specications subject to change without notice.Pressure Ranges+P

Página 3 - Threaded Connections Letter

TMAmerican Sensor Technologies • 450 Clark Dr., Mt. Olive, NJ 07828 • phone (973) 448-1901 • fax (973) 448-1905 • email: [email protected]

Comentários a estes Manuais

Sem comentários

Environmental-express podręczniki

Wykaz produktów Environmental-express zawiera 15 instrukcje obsługi i przewodniki dla 15 modeli w 2 typu urządzeń

Ekwipunek
Modele Rodzaj dokumentu
AutoBlock II Instrukcja Użytkownika   Environmental Express AutoBlock II User Manual, 44 strony
HotBlock Ogden 3200 Instrukcja Użytkownika   Environmental Express HotBlock Ogden 3200 User Manual, 18 strony
SimpleDist Instrukcja Użytkownika   Environmental Express SimpleDist User Manual, 24 strony
Soil-Cell Instrukcja Użytkownika   Environmental Express Soil-Cell User Manual, 15 strony
MicroBloc Instrukcja Użytkownika   Environmental Express MicroBloc User Manual, 20 strony